To connect my Sandisolar inverter to Home Assistant, I needed some kind of adapter in between. I decided for ESP32C3 with Tasmota firmware. RS232 connection at RJ45 connector is the same like other Chinese converters.
The following registers are read only holding registers for the most common values.
| Addr. dec. | Addr. HEX | Format | Function |
|---|---|---|---|
| 202 | 00CA | /10 | AC Mains 230V |
| 203 | 00CB | /100 | AC 50 Hertz |
| 204 | 00CD | /10 | Total Out Voltage 230V |
| 00D0 | /1 | Total Out Power W | |
| 210 | 00D2 | /10 | Out1 Voltage 230V |
| 212 | 00D4 | /100 | Out1 50 Hertz |
| 213 | 00D5 | /1 | Out1 Power W |
| 00D6 | /1 | Hauslast Scheinleistung ?? | |
| 215 | 00D7 | /10 | Battery Voltage |
| 216 | 00D8 | s/10 | Battery current +/-A |
| 219 | 00DB | /10 | PV Voltage V |
| 220 | 00DC | /10 | PV Current A |
| 223 | 00DF | /1 | PV_Power W |
| 224 | 00E0 | /1 | Battery Charge Power W |
| 00E2 | /1 | Temperature1 °C | |
| 00E3 | /1 | Temperature2 °C | |
| 00E4 | /1 | Temperature3 °C | |
| 232 | 00E8 | s/10 | Battery current +/-A |
| 244 | 00F4 | /10 | Out2 Voltage 230V |
; GPIO's auf NONE stellen! >M 1 ; Optimierte Abfrage der Live-Register deines SD-4862W-II-EU (9600 Baud, Slave 1) +1,20,m,0,9600,PowMr,21,3,010300ca,010300cc,010300d0,010300d2,010300d4,010300d6,010300d8,010300da,010300f0,010300f2,010300f4,010300dc,010300de,010300e0,010300e2,010300e4,010300e6,010300e8 ; Netz (Grid) - Block @i0 (00CA, 00CB, 00CC ) 1,010304UUuuxxxx@i0:10,AC Voltage,V,AC_Voltage,1 1,010304xxxxUUuu@i0:100,AC Frequenz,Hz,AC_Freq,1 1,010304UUuuxxxx@i1:1,CC AC Leistung?,W,AC_power,0 1,010304xxxxUUuu@i1:10,CD Spannung OUT3,V,CD,1 ; Batterie Strom - Block @i1 (00D0, signed ssSS) 1,010304SSssxxxx@i2:10,D0,A,Reg_D0,1 1,010304xxxxUUuu@i2:10,D1,W,Reg_D1,1 ; Ausgang (Load) - Block @i2 & @i3 (00D2, 00D4, 00D5) 1,010304UUuuxxxx@i3:10,Spannung OUT1,V,Out_Voltage,1 1,010304xxxxUUuu@i3:10,D3,A,Reg_D3,1 1,010304UUuuxxxx@i4:100,Frequenz OUT1,Hz,Out_Freq,1 1,010304xxxxSSuu@i4:1,Leistung OUT1,W,Out_Power,0 ; Ausgang Scheinleistung & Batterie - Block @i4 & @i5 (00D6, 00D7, 00D8) 1,010304UUuuxxxx@i5:1,Ausgang Scheinleistung,VA,Out_VA,0 1,010304xxxxUUuu@i5:10,Battery Voltage,V,Batt_Voltage,1 1,010304SSssxxxx@i6:10,Battery Current,A,Batt_Current,1 ; Solar (PV) - Block @i6 (00DA & 00DB) 1,010304UUuuxxxx@i7:10,DA,V,REG_DA,1 1,010304xxxxUUuu@i7:10,PV Spannung,V,PV_Voltage,1 ; Temperatur - Block @i7 (00F0) 1,010304UUuuxxxx@i8:10,Inverter Temperatur,°C,Inv_Temp,1 1,010304xxxxUUuu@i8:10,F1,W,Reg_F1,1 1,010304UUuuxxxx@i9:10,F2,V,Reg_F2,1 1,010304xxxxUUuu@i9:10,F3 Spannung?,V,RegF3,1 1,010304UUuuxxxx@i10:10,F4 Spannung OUT2,V,RegF4,1 1,010304xxxxUUuu@i10:10,F5,W,RegF5,1 1,010304UUuuxxxx@i11:10,DC,W,RegDC,1 1,010304xxxxUUuu@i11:10,DD,W,RegDD,1 1,010304UUuuxxxx@i12:10,DE,W,RegDE,1 1,010304xxxxUUuu@i12:1,DF PV Leistung,W,PV_Power,0 1,010304SSssxxxx@i13:1,E0 Battleistung,W,Batt_Power,0 1,010304xxxxUUuu@i13:10,E1,W,RegE1,1 1,010304UUuuxxxx@i14:10,E2,W,RegE2,1 1,010304xxxxUUuu@i14:10,E3,W,RegE3,1 1,010304UUuuxxxx@i15:10,E4,W,RegE4,1 1,010304xxxxUUuu@i15:10,E5,W,RegE5,1 1,010304UUuuxxxx@i16:10,E6,W,RegE6,1 1,010304xxxxUUuu@i16:10,E7,W,RegE7,1 1,010304SSssxxxx@i17:10,E8 Battery current,A,RegE8,1 1,010304xxxxUUuu@i17:10,E9,W,RegE9,1 #