User Tools

Site Tools


technik:sandisolar_sd-4862w-ii-eu

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
technik:sandisolar_sd-4862w-ii-eu [2026/11/15 08:19]
ich ↷ Page name changed from technik:sd-4862w-ii-eu to technik:sandisolar_sd-4862w-ii-eu
technik:sandisolar_sd-4862w-ii-eu [2026/11/15 20:58] (current)
ich [Modbus Register List for SD-4862W-II-EU]
Line 1: Line 1:
-====Solarconverter SD-4862W-II-EU====+====== Solarconverter SD-4862W-II-EU with Tasmota ====== 
 + 
 +To connect my **Sandisolar inverter** to **Home Assistant**, I needed some kind of adapter in between. I decided for **ESP32C3** with **Tasmota** firmware. RS232 connection at RJ45 connector is the same like other Chinese converters.  
 +  * [[https://github.com/arendst/Tasmota]] 
 +  * {{ :technik:PowMr1_sch.pdf|Schaltplan}} 
 + 
 +====Modbus Register List for SD-4862W-II-EU==== 
 +The following registers are read only holding registers for the most common values. 
 + 
 +<dtable> 
 +^Addr. dec.^Addr. HEX^ Format ^ Function   ^  
 +|202|00CA|/10|AC Mains 230V | 
 +|203|00CB|/100|AC 50 Hertz| 
 +|205|00CD|/10|Total Out Voltage 230V | 
 +|206|00CE|/10|Total Out Current A | 
 +|207|00CF|/100|Total Out Frequ. Hz | 
 +|208|00D0|/1|Total Out Power W| 
 +|210 |00D2 |/10 |Out1 Voltage  230V | 
 +|210 |00D2 |/10 |Out1 Current A | 
 +|212 |00D4 |/100 |Out1 50 Hertz | 
 +|213 |00D5 |/1 |Out1 Power W - defect? | 
 +|    |00D6 |/1 |  Hauslast Scheinleistung ?? | 
 +|215 |00D7 |/10 |Battery Voltage | 
 +|216 |00D8 |s/10 |Battery Current +/-A | 
 +|217 |00D9 |s/1 |Battery Power +/-W | 
 +|219 |00DB |/10 |PV Voltage V| 
 +|220 |00DC |/10 |PV Current A| 
 +|223 |00DF |/1 |PV_Power W| 
 +|224 |00E0 |/1 |Battery Charge Power W| 
 +| |00E2 |/1 |Temperature1 °C| 
 +| |00E3 |/1 |Temperature2 °C| 
 +| |00E4 |/1 |Temperature3 °C| 
 +|232 |00E8 |s/10 |Battery current +/-A | 
 +|244 |00F4 |/10 |Out2 Voltage 230V | 
 + 
 +</dtable> 
 + 
 +====Tasmota script for SD-4862W-II-EU==== 
 + 
 + 
 +<code ini Tasmota Script.txt>  
 +; GPIO's auf NONE stellen! 
 + 
 +>M 1 
 +; Optimierte Abfrage der Live-Register deines SD-4862W-II-EU (9600 Baud, Slave 1) 
 ++1,20,m,0,9600,PowMr,21,3,010300ca,010300cc,010300d0,010300d2,010300d4,010300d6,010300d8,010300da,010300f0,010300f2,010300f4,010300dc,010300de,010300e0,010300e2,010300e4,010300e6,010300e8 
 + 
 +; Netz (Grid) - Block @i0 (00CA, 00CB, 00CC ) 
 +1,010304UUuuxxxx@i0:10,AC Voltage,V,AC_Voltage,1 
 +1,010304xxxxUUuu@i0:100,AC Frequenz,Hz,AC_Freq,1 
 +1,010304UUuuxxxx@i1:1,CC AC Leistung?,W,AC_power,0 
 +1,010304xxxxUUuu@i1:10,CD Spannung OUT3,V,CD,1 
 + 
 +; Batterie Strom - Block @i1 (00D0, signed ssSS) 
 +1,010304SSssxxxx@i2:10,D0,A,Reg_D0,1 
 +1,010304xxxxUUuu@i2:10,D1,W,Reg_D1,1 
 + 
 +; Ausgang (Load) - Block @i2 & @i3 (00D2, 00D4, 00D5) 
 +1,010304UUuuxxxx@i3:10,Spannung OUT1,V,Out_Voltage,1 
 +1,010304xxxxUUuu@i3:10,D3,A,Reg_D3,1 
 +1,010304UUuuxxxx@i4:100,Frequenz OUT1,Hz,Out_Freq,1 
 +1,010304xxxxSSuu@i4:1,Leistung OUT1,W,Out_Power,0 
 + 
 +; Ausgang Scheinleistung & Batterie - Block @i4 & @i5 (00D6, 00D7, 00D8) 
 +1,010304UUuuxxxx@i5:1,Ausgang Scheinleistung,VA,Out_VA,0 
 +1,010304xxxxUUuu@i5:10,Battery Voltage,V,Batt_Voltage,1 
 +1,010304SSssxxxx@i6:10,Battery Current,A,Batt_Current,1 
 + 
 +; Solar (PV) - Block @i6 (00DA & 00DB) 
 +1,010304UUuuxxxx@i7:10,DA,V,REG_DA,1 
 +1,010304xxxxUUuu@i7:10,PV Spannung,V,PV_Voltage,1 
 + 
 +; Temperatur - Block @i7 (00F0) 
 +1,010304UUuuxxxx@i8:10,Inverter Temperatur,°C,Inv_Temp,1 
 +1,010304xxxxUUuu@i8:10,F1,W,Reg_F1,1 
 + 
 +1,010304UUuuxxxx@i9:10,F2,V,Reg_F2,1 
 +1,010304xxxxUUuu@i9:10,F3 Spannung?,V,RegF3,1 
 + 
 +1,010304UUuuxxxx@i10:10,F4 Spannung OUT2,V,RegF4,1 
 +1,010304xxxxUUuu@i10:10,F5,W,RegF5,1 
 + 
 +1,010304UUuuxxxx@i11:10,DC,W,RegDC,1 
 +1,010304xxxxUUuu@i11:10,DD,W,RegDD,1 
 + 
 +1,010304UUuuxxxx@i12:10,DE,W,RegDE,1 
 +1,010304xxxxUUuu@i12:1,DF PV Leistung,W,PV_Power,0 
 + 
 +1,010304SSssxxxx@i13:1,E0 Battleistung,W,Batt_Power,0 
 +1,010304xxxxUUuu@i13:10,E1,W,RegE1,1 
 + 
 +1,010304UUuuxxxx@i14:10,E2,W,RegE2,1 
 +1,010304xxxxUUuu@i14:10,E3,W,RegE3,1 
 + 
 +1,010304UUuuxxxx@i15:10,E4,W,RegE4,1 
 +1,010304xxxxUUuu@i15:10,E5,W,RegE5,1 
 + 
 +1,010304UUuuxxxx@i16:10,E6,W,RegE6,1 
 +1,010304xxxxUUuu@i16:10,E7,W,RegE7,1 
 + 
 +1,010304SSssxxxx@i17:10,E8 Battery current,A,RegE8,1 
 +1,010304xxxxUUuu@i17:10,E9,W,RegE9,1 
 +# 
 + 
 +</code> 
technik/sandisolar_sd-4862w-ii-eu.1794727172.txt.gz · Last modified: 2026/11/15 08:19 by ich