 ===== Tasmota ModBus Script ===== ===== Tasmota ModBus Script =====
  
-I needed the script to access my Modbus based solar inverter PowMr. PowMr inverter are all very similar. Luckily +I needed the script to access/read my Modbus based solar inverter PowMr. PowMr inverter are all very similar. Luckily 
   * [[https://github.com/leodesigner/powmr_comm]]    * [[https://github.com/leodesigner/powmr_comm]] 
 investigated already on the registers for these PowMr inverters. investigated already on the registers for these PowMr inverters.
  
-HW: GPIO20/21(Rx,Tx) configured as 'None' where used.+HW: GPIO20/21(Rx,Tx) configured as ''None'' where used.
  
 Tasmota Scripting was the most ugly part of the project. Tasmota Scripting was the most ugly part of the project.
Line 158: Line 158:
 PowMr inverter lacks the AC input  power measurement. For this reason I added a PZEM004 module for power measurement, which is already fully supported by Tasmota - simply by selecting Rx and Tx-PZEM004 in the Tasmota pin configuration menue. PowMr inverter lacks the AC input  power measurement. For this reason I added a PZEM004 module for power measurement, which is already fully supported by Tasmota - simply by selecting Rx and Tx-PZEM004 in the Tasmota pin configuration menue.
  
 +{{:technik:config_pzem.png?200|}}
  
 ===== Tasmota-Berry ModBus Script ===== ===== Tasmota-Berry ModBus Script =====
-Dies sind Ideen für ein schöneres Berry Script. Dafür muß in der Pin configuration für pin20/21 statt 'None', 'ModBusRx/Tx ausgewählt werden, um das 'ModBusSend' Kommando zu ermöglichen.+The above script lacks the possibility of changing values on the modbus device (just reading is possible). 
 + 
 +Dies sind Ideen für ein schöneres Berry Script. Dafür muß in der Pin configuration für pin20/21 statt ''None'', ''ModBr Rx/Tx'' ausgewählt werden, um das ''ModBusSend'' Kommando auf der Console zu ermöglichen
 + 
 +<code txt console commands> 
 +ModbusBaudrate 2400 
 +ModBusSend {"deviceaddress": 1, "functioncode": 4, "startaddress": 4501, "type": "uint16", "count": 1} 
 +</code> 
 + 
 +Zunächst antwortet dieses Kommando nicht mit ''ModBusReceive''
 + 
 +Andere User schreiben, dass dieser Berry Mode leider Crash gefährdet ist.
  